10.
a--para 1-3b
Maximum permitted relative level is 40 dB below normal level at the
TLP (-15 dBm). This means the harmonic level must be no greater than -55
dBm to satisfy the harmonic requirement of parameter S3. The measured level
of second harmonic energy is -42 dBm, which exceeds the tolerance by 13 dB.
The relative level of harmonic energy is -27 dBm0 (27 dB below TLP).
11.
b--para 1-4
Second harmonic of 1,000 Hz is 2,000 Hz.
2,000 - 1,125 = 875 Hz
12.
d--para 1-5a
13.
b--para 1-6c(7)
14.
c--para 1-7c(2)(f), B of figure 2-12
15.
c--para 1-7c(l)(f)
16
a--para 1-7
17.
b--para 1-7c(1)(e)
18.
a-para 1-7c(1)(f), (2)(f)
19.
a--para 1-8
20.
b--para 1-7c(1)(b), 2-8c(1)(b)
The oscillator output voltage is adjusted to 0 dBm0, which is another
way of saying that the oscillator output signal will equal the normal level
of the signal at the point of test.
21.
b--para 1-8c(1)(b)
22.
d--para 1-8c(1)(c)
96