(2) Pole steps for strand-mounted distribution terminals with extension arms. When the
strand is supported by an extension arm or fixture, a double step should be installed at step C as shown
in Figures 1-23 and 1-24. For terminals mounted to the left of the extension arm, two additional steps
are installed on the quarter opposite step D as shown in Figure 1-23. For terminals mounted to the right
of the extension arm, one additional line step is installed under step C as shown in Figure 1-23. Step D
is not installed, but two additional steps are installed on the quarter in place of step D.
Figure 1-23. Location of pole steps below stand-mounted
terminal placed to the right of an extension arm.
(3) Pole steps for pole-mounted distribution terminals. Where terminals without protectors
are mounted on the pole, install double steps at D and at the two successive lower pole steps as shown in
Figure 1-25. Where protectors are mounted on the pole, install a double pole step at step D and
successive lower pole steps until the lowest double step is below the lowest protectors as shown in
Figure 1-26.
SS0439
1-34