19. AN/TTC-47 NCS.
Status: To be determined; NSN: To be determined
General Information
The NCS is configured in two S-250( )/G shelters-a wit g shelter and an operations shelter, each
transported on an M-1037 (HMMWV). The NCS is the hub of the MSE node providing network
interface for the subscriber access elements. The ON-306/TTC-47 switching shelter provides the
external interface, circuit switching, and associated functions. The OL-413/TTC-47 operations shelter
provides the central processing and operator interface functions. The NCS provides automatic
subscriber finding features which allow permanent subscriber address assignment and negates the need
for knowledge of subscriber geographical location and switch affiliation at the subscriber level. Power
to both assemblages is provided by a PU-753/M, 10-kW, trailer-mounted, diesel generator.
Major Components
ON-306
OL-413
Shelter S-250/G
1
Shelter S-250E/G
1
Switch subsystem AN/TTC-47:
LCSP*
1
Switching processor system*
1
Plasma display unit*
1
TDSGM
2
Trunk encryption device KG-194A's
15
8
Automatic key distribution control KGX-93
1
Transition unit HGF-93
1
Net control device KYX-15
1
Communication modem
1
VINSON COMSEC KY-57
1
Environmental control unit
1
Junction box J-1077/U
2
Intercommunications station LS-147
1
1
Workstation
1
DNVT TA-1035/U
1
Signal cable CX-4566
2
Intershelter cables
6
Power cables CX-7453 and CX-7705 **
1
Packet switches AN/TYC-19 and -20
1
* Part of AN/TTC-47
** Shelter power cables are connected in series
1-27
SS 0029