b. Arc protection is usually achieved by sensing a change in body current and firing a triggered spark gap
which crowbars (instantly removes) the beam supply voltage. Protection from excessive reflected power and
RF arcing is achieved by removing RF drive from the klystron when the input-waveguide solid-state switch is
reverse biased.
2-23