Figure 2-3.
(2) Output levels from the line are taken relative to the received
level at 1.0-kHz reference frequency. A separate level reading is taken for
2-4).
(3) Establish a standard level at the transmitting end of the circuit
by placing the MEAS-CAL switch of the patch panel to the CAL position and by
adjusting the AMPLITUDE control for the oscillator for an output of 0 dBm at
1,000 Hz. (In the CAL position the oscillator is connected directly to the
level is set, return the MEAS-CAL switch back to the MEAS position. Do not
make any adjustments to the signal level. If the level varies, it can be
attributed to impedance mismatch between the 600-ohm oscillator output and
the line under test. Adjust the FREQ control of the oscillator to the first
frequency indicated on the frequency response data sheet (figure 2-4)
without making any adjustments to the signal level.
If at any selected
frequency the oscillator output level varies from the level observed at
1,000 Hz, set the MEAS-CAL switch on the patch panel to CAL and adjust the
AMPLITUDE control of
58