CONTROL, INDICATOR, OR CONNECTOR
FUNCTION
NOTE. Lamps will operate
only at voltage selected
by KELVIN TEMPERATURE
SELECTOR SWITCH.
Remote timer
operation...Sets up conver-
ter output to be
low or to be con-
trolled by in-
terval timer.
NOTE. If interval timer is not
used, lamps will operate at re-
duced voltage until switch is
interval timer is used, lamps
will operate at reduced volt-
age until interval timer oper-
ates. Then, lamps will oper-
ate at voltage selected by
kelvin temperature selector
switch.
When cycle of in-
terval timer is over, lamps
will again operate at reduced
voltages.
Kelvin temperature
selector switch......................
Seven-position rotary switch.
POSITION
FUNCTION
1........... Selects output of
120V ac at 2900K.
2........... Selects output of
131V ac at 2992K.
3........... Selects output of
142V ac at 3084K.
4........... Selects output of
153V ac at 3176K.
5........... Selects output of
164V ac at 3268K.
6........... Selects output of
175V ac at 3360K.
7........... Selects output of
186V ac at 3450K.
NOTE. The above outputs are based
on an input voltage of 115V ac.