(2) Allow the calculated amount of time to pass.
(3) Press the cable release plunger a second time to close the
shutter.
d. Replace the slide in the filmholder with the black (dull) side of
the slide out to indicate the film has been exposed.
e. Set the locking screw on the filmholder to hold the slide in
position; remove the filmholder from the focusing back.
f. Shut down the camera set (para 35).
g. Process the exposed film IAW film manufacturer's instructions.
35
Stopping Procedures
If the camera set is to be placed in a standby condition, follow the
procedures in a below. If the camera set is to be shut down overnight or
for an extended period of time, follow the procedures in b below.
a. Standby shutdown.
(1) Set the MANUALTIMER switch (figure 7) on the converter to REMOTE
TIMER OPERATION; the light assembly lamps will glow dimly.
(2) Place the lens cap on the lens.
b. Extended shutdown.
(1) Set the MAIN POWER switch (figure 7) on the converter to OFF.
(2) Place the lens cap on the lens.
38