REFERENCE
LEARNING
ANSWER
EVENT
PARAGRAPH
14.
c
3
d and figure 1-6
The input signal level drops to -28 dBm, 2 dB less than the value
shown in figure 3-6.
Attenuator 1 loss must therefore be changed
from 22 to 20 dB so as to maintain the output level of amplifier 1 at
the required -2 dBm value for equal-level patching.
15.
d
3
d and figure 1-6
The signal level must be reduced; therefore the attenuator loss must
be increased.
Since the signal level must drop from 12 dBm to 10
dBm, the attenuator loss must increase from 21 to 23 dB.
16.
a
4
a and b
17.
d
4
d
18.
a
5
b, (2)
35