3-5
Installation Instructions
Siting.
The print processor may be placed at any convenient waist-
high location that will support its weight, not farther than 7.5 feet from a
grounded receptacle.
For greater ease of operation, the print processor
should be located as close as possible to the printer or enlarger that will
be used for exposing the stabilization type paper. Check to see that the
print processor is level (para 3-8c, TM 11-6780-225-12, Appendix A, if the
print processor is supplied as a part of the ES-82A). Check to see that the
safelight in use has a Wratten Series OC filter and a 15-watt bulb and that
it is not located closer than 4 feet to the print processor.
3-6
Assembly of Components
(1) Screw the drain bottle caps securely on the threaded ends of the
(2) Insert the stabilizer drain bottle (red label) inside and to the
rear of the base assembly, with the top opening facing up.
(3) Insert the activator drain bottle (black label) inside and to the
front of the base assembly.