SECTION 5
FIRST ECHELON (OPERATOR) MAINTENANCE
330 Operator's Maintenance
The photographic laboratory technician, the operator of the drier, is
responsible for daily, weekly, and 200hour preventive maintenance routines.
Corrective maintenance at this level requires replacement of air filter
only. Necessary repairs or replacement, noted during inspection and
requiring correction by a higher echelon, will be indicated by the operator
on the DA Form 2404.
331 Tools and Materials Required
The tools and materials required by the operator for maintaining the
drier are listed below.
ITEM
USED TO
Chamois
Clean the cabinet.
Cleaning brush, 1inch dia
Remove dust from corners and from motor
and fan.
Cleaning Compound (Fed
Remove stubborn dirt and grime.
Stock No. 79303959542)
Screwdrivers TL358/U
Tighten cabinet hardware
and TL360/U
and motor and fan mounting.
Wrench TL111
Pliers TL13A
Knife TL29
Lintfree cloth
Remove dust from drier.
Sponge
Wash the cabinet.
Oil, Engine, Heavy Duty
Lubricate the motor.
(OE10)
241