SECTION 5
FIRST ECHELON (OPERATOR) MAINTENANCE
3-30 Operator's Maintenance
The photographic laboratory technician, the operator of the drier, is
responsible for daily, weekly, and 200-hour preventive maintenance routines.
only.
Necessary repairs or replacement, noted during inspection and
requiring correction by a higher echelon, will be indicated by the operator
on the DA Form 2404.
3-31 Tools and Materials Required
The tools and materials required by the operator for maintaining the
drier are listed below.
ITEM
USED TO
Chamois
Clean the cabinet.
Cleaning brush, 1-inch dia
Remove dust from corners and from motor
and fan.
Cleaning Compound (Fed
Remove stubborn dirt and grime.
Stock No. 7930-395-9542)
Screwdrivers TL-358/U
Tighten cabinet hardware
and TL-360/U
and motor and fan mounting.
Wrench TL-111
Pliers TL-13-A
Knife TL-29
Lint-free cloth
Remove dust from drier.
Sponge
Wash the cabinet.
Oil, Engine, Heavy Duty
Lubricate the motor.
(OE-10)
241