b. Possible bad equipment. The items of equipment that may cause the
symptom in EPC step 2a are: commander's C-2298, CX-4723 (between J801 on the
C-2298 and J504 on the AM-1780), and AM-1780 (Figure 38).
The defective
item can be found by individually disconnecting items of equipment from the
circuit.
Figure 38.
Commander's intercom keying circuit, continuous keying.
c. Test procedure 16.
Disconnect the CX-4723 from J801 on the commander's C-2298.
If the relays in the AM-1780 click, the
commander's
C-2298
contains a short. Send to IDS for repair.
If the AM-1780 relays do not click the C-2298 is not bad.
Disconnect the CX-4723 from J504 on the AM-1780.
40